s7sciences.com
S7 summary & reports
GLP-3 RT · 10 mg
lyophilized vial
Supplier reports available. For the S7 stock documentation below, the owner confirms current on-hand stock is from the latest supplier batches. Packaging lot numbers were not independently read.
Supplier-published references. Not matched to current S7 stock or packaging. Match the complete lot number on your vial to the original report; a matching product name or strength alone does not confirm the batch.
Laboratory reports
Content & purity
Amino Science Labs- Testing laboratory
- Freedom Diagnostics
- Report date
- Oct 14, 2026
- Report number
- 2610139096
- Source lot
- AS-RT10-2026-0019
| Compound | Specification | Measured content | Purity |
|---|---|---|---|
| GLP-3 Reta | 10 mg | 11.05 mg | 99.96% |
- Test method
- HPLC-UV / LC-MS
- Appearance
- White lyophilized powder
- Identity result on report
- Confirmed
- Results apply to the laboratory sample.
- Endotoxin, sterility and heavy-metal results are not reported in this document.
Read original report here
Open report in a separate tab if your browser cannot display PDFs here.
Content & purity
MSAmino- Testing laboratory
- Horizon Analytical
- Report date
- Aug 7, 2026
- Report number
- 1022256
- Source lot
- MSA-8607214
| Compound | Specification | Measured content | Purity |
|---|---|---|---|
| Retatrutide | 10 mg | 9.74 mg | 99.72% |
- Test method
- UPLC/MS
- Appearance
- White lyophilized powder
- Results apply to the identified tested sample.
- No sterility or heavy-metal test results reported.
- Identity field is N/A; named compound-test results are transcribed, not an independent identity certification.
Read original report here
Open report in a separate tab if your browser cannot display PDFs here.
Endotoxin analysis
MSAmino- Testing laboratory
- Horizon Analytical
- Report date
- Aug 7, 2026
- Report number
- 1022311
- Source lot
- MSA-8607214
- Endotoxin
- <0.05 EU/mL
- Results apply to the identified tested sample.
- The report does not state the specific endotoxin assay method.
- An endotoxin result is not a sterility test. No sterility or heavy-metal results are reported.
Read original report here
Open report in a separate tab if your browser cannot display PDFs here.
Original report · Lot DPS-1507786
Privilege BioLabs- Testing laboratory
- Horizon Analytical
- Report date
- Aug 13, 2026
- Report number
- 1024168 · 1024167
- Source lot
- DPS-1507786
- Report sample
- Retatrutide
- Tests included
- content/purity by UPLC/MS · UPLC/MS chromatograms · endotoxin
Read original report here
Open report in a separate tab if your browser cannot display PDFs here.
Original report · Lot BTCH-PE-99-334
Privilege BioLabs- Testing laboratory
- Optiq Health Labs, LLC
- Report date
- Sep 4, 2026
- Report number
- 1190.OPT.260901-R1-WL06
- Source lot
- BTCH-PE-99-334
- Report sample
- GLP-3R 10mg
- Tests included
- net content by HPLC · purity by RP-HPLC · endotoxin by LAL
- The date shown is the report issue date; a separate analysis date is not stated.
Read original report here
Open report in a separate tab if your browser cannot display PDFs here.